How to repressurise a boiler: step by step for Worcester, Vaillant, Ideal and Baxi

To repressurise a boiler, turn it off, open the filling loop or filling key slowly until the pressure gauge reads about 1 to 1.5 bar, then close it and turn the boiler back on. It takes a few minutes and you don’t need any tools on most boilers. If the pressure keeps dropping and you have to top it up again within days, something is letting water out, and that needs finding rather than topping up.

What should my boiler pressure be?

Most combi and system boilers should read about 1 to 1.5 bar when the heating is off and cold. It rises when the heating is on, often to around 2 bar, and that’s normal.

  • Below 1 bar: the pressure is low. The boiler may show a fault code or stop working.
  • Above about 2.5 bar when hot: the pressure is too high. Don’t add any water. See boiler pressure too high instead.

If you have a tank in the loft and no pressure gauge, you have an open vent (regular) boiler, which doesn’t need topping up like this. Not sure? Our guide to what type of boiler you have will help.

Before you start

  • Turn the boiler off and let it cool. Topping up a hot system gives a false reading.
  • Find your boiler’s manual, or look up the model online. The filling parts look different from one boiler to another.
  • Never take the cover off the boiler. Everything you need is underneath it.
  • Have a towel handy in case a few drops come out.

How to repressurise a boiler with a filling loop

A filling loop is a short silver hose under the boiler, with a valve at one or both ends. Many Baxi, Vaillant and Ideal boilers have one.

  1. Check both ends of the hose are firmly connected. If it’s been taken off, screw it back on by hand.
  2. Slowly open the first valve, then the second. You’ll hear water flowing in.
  3. Watch the pressure gauge. When it reaches about 1 to 1.5 bar, close both valves.
  4. If your filling loop is the detachable kind, take it off and keep it safe. Have a towel ready for the drop of water left inside.
  5. Turn the boiler back on. If it shows a fault, press reset. Our guide to boiler not working covers the other checks.

Boilers with a filling key or a lever

Some boilers have the filling loop built in, with no hose to see.

  • Filling key: some Worcester Bosch Greenstar boilers come with a plastic filling key that clips into the bottom of the boiler. You push it in, turn it, then open the blue tap or turn the key until the gauge reads about 1 to 1.5 bar.
  • Blue lever: some Worcester Bosch and Ideal models have a lever or tap under the boiler instead. Turn it slowly, watch the gauge, then turn it back.
  • Vaillant: many ecoTEC models have a blue tap or a key under the boiler. Again, open it slowly and close it at the right pressure.

The manual shows exactly where yours is. If you can’t find the filling parts at all, don’t force anything. Give us a call and we’ll talk you through it.

After you’ve topped it up

  • Check under the boiler for any drips from the valves you’ve just used.
  • Run the heating and check the pressure once it’s warm. A rise to around 2 bar is normal.
  • Check it again the next day. If it’s stayed put, the job’s done.

If you bled your radiators recently, that often explains the drop: letting air out lowers the pressure. See how to bleed a radiator.

If the pressure keeps dropping

Having to top up once or twice a year is normal. Having to do it every few days or weeks is not. Water is getting out somewhere, usually through:

  • a small leak on a pipe, radiator or valve
  • the pressure relief valve, which drips through a copper pipe outside
  • a failed expansion vessel inside the boiler
  • a leak inside the boiler itself

Our guide to why your boiler keeps losing pressure explains each one and the checks you can do. Topping up again and again adds fresh water to the system each time, which can speed up rust and sludge in your radiators.

Our boiler repair team can find out why your boiler is losing pressure and fix it. MS HEATING AND PLUMBING has been looking after boilers across Birmingham and Solihull for over 29 years. Our engineers are Gas Safe Registered, and we’re a Which? Trusted Trader.

Frequently asked questions

How do I repressurise my boiler?

Turn the boiler off, open the filling loop or filling key slowly until the gauge reads about 1 to 1.5 bar, close it, then turn the boiler back on and press reset if needed.

What should my boiler pressure be?

About 1 to 1.5 bar when the heating is off and cold. It rises when the heating is on, often to around 2 bar, which is normal.

Is it safe to repressurise a boiler myself?

Yes. Topping up the pressure is something boiler makers expect you to do yourself. Don’t take the cover off the boiler or touch anything inside it.

How often should I need to top up my boiler pressure?

Once or twice a year at most. If you’re topping up every few days or weeks, water is escaping somewhere and the cause needs finding.

What if I put too much pressure in?

Bleed a radiator to let a little water out until the gauge drops back to about 1.5 bar. Our guide to boiler pressure too high explains how.

Why can’t I find a filling loop on my boiler?

Some boilers have it built in, with a filling key or a lever underneath instead of a hose. Your boiler’s manual shows where it is.

Boiler still losing pressure?

Send us a photo of the pressure gauge and the pipes under your boiler on WhatsApp, and tell us how often you’re topping up. If you have no heating or hot water, give us a call on 0121 709 0000.

Radiator or radiator valve leaking: what to do

A leaking radiator usually comes from a valve, not the radiator itself. Here’s how to find the leak, stop the damage and tell whether it needs a repair.

Read the full article: Radiator or radiator valve leaking: what to do

Got a Question?

Our engineers are happy to advise. No sales pressure, just honest help from a local team you can trust.

Get a Free Quote

Fill in the form below and we’ll get back to you shortly.

Let’s keep in touch!

Enjoy money-saving tips, helpful service reminders and special offers by email.

We’ll use your details to reply to your enquiry. See our Privacy Policy.

We’ll do our best to call you at your preferred time. If we’re running slightly off schedule, we’ll still make sure to get in touch as soon as we can.